Robust SCBA resistant to extreme temperatures – EN 137
GPAL-QS: the robust SCBA resistant to extreme temperatures
The GPAL-QS is a robust SCBA designed to protect the respiratory tract and face of professionals operating in non-breathable atmospheres. It is particularly suited for use in the presence of toxic gases, fire smoke, dusts or toxic aerosols. It is also suitable for oxygen-deficient atmospheres where the oxygen concentration is below 17%.
The GPAL-QS incorporates the latest technological innovations in high-pressure breathing quality and demand valves. Compliant with EN 137, it is classified as a type 1 apparatus for industrial use and a type 2 apparatus for firefighting operations. It must be used with a TOTAL III full face mask compliant with EN 136 class 3.
Why choose the GPAL-QS?
- Self-contained breathing apparatus designed for non-breathable atmospheres.
- Protection of the respiratory tract and face when used with a suitable full face mask
- Lightweight composite chassis providing excellent resistance to mechanical stress and extreme temperatures.
- Padded straps enhancing wearer comfort during operations.
- 4-position rack system allowing quick and easy adjustment of the chassis height.
- Quick and secure fastening system with adjustable locking.
- Quick-adjust cylinder strap with secure locking buckle.
- Fastening system suitable for different cylinder diameters and twin-cylinder set.
- Operating duration of 20 to 60 minutes, depending on cylinder type and wearer consumption.
Designed for the most demanding sectors, the GPAL-QS is particularly suited to professionals workingin fire and rescue services, the military, defence and CBRN sectors, and the chemical and petrochemical industries. It supports operators during interventions requiring respiratory protection in hazardous atmospheres.
The operating duration varies according to the cylinder used and the wearer’s air consumption. Physical effort directly influences breathing rate and therefore air consumption. The GPAL-QS must also be inspected regularly by trained and competent personnel in accordance with the periodic maintenance schedule specified in its user instructions.
Thanks to its robust chassis, adjustment systems and secure cylinder fastening, the GPAL-QS combines durability, comfort and ease of use. It therefore provides a suitable solution for professionals seeking a reliable self-contained breathing apparatus for industrial operations and firefighting activities.
Robust SCBA resistant to extreme temperatures – EN 137
GPAL-QS: the robust SCBA resistant to extreme temperatures
The GPAL-QS is a robust SCBA designed to protect the respiratory tract and face of professionals operating in non-breathable atmospheres. It is particularly suited for use in the presence of toxic gases, fire smoke, dusts or toxic aerosols. It is also suitable for oxygen-deficient atmospheres where the oxygen concentration is below 17%.
The GPAL-QS incorporates the latest technological innovations in high-pressure breathing quality and demand valves. Compliant with EN 137, it is classified as a type 1 apparatus for industrial use and a type 2 apparatus for firefighting operations. It must be used with a TOTAL III full face mask compliant with EN 136 class 3.
Why choose the GPAL-QS?
- Self-contained breathing apparatus designed for non-breathable atmospheres.
- Protection of the respiratory tract and face when used with a suitable full face mask
- Lightweight composite chassis providing excellent resistance to mechanical stress and extreme temperatures.
- Padded straps enhancing wearer comfort during operations.
- 4-position rack system allowing quick and easy adjustment of the chassis height.
- Quick and secure fastening system with adjustable locking.
- Quick-adjust cylinder strap with secure locking buckle.
- Fastening system suitable for different cylinder diameters and twin-cylinder set.
- Operating duration of 20 to 60 minutes, depending on cylinder type and wearer consumption.
Designed for the most demanding sectors, the GPAL-QS is particularly suited to professionals workingin fire and rescue services, the military, defence and CBRN sectors, and the chemical and petrochemical industries. It supports operators during interventions requiring respiratory protection in hazardous atmospheres.
The operating duration varies according to the cylinder used and the wearer’s air consumption. Physical effort directly influences breathing rate and therefore air consumption. The GPAL-QS must also be inspected regularly by trained and competent personnel in accordance with the periodic maintenance schedule specified in its user instructions.
Thanks to its robust chassis, adjustment systems and secure cylinder fastening, the GPAL-QS combines durability, comfort and ease of use. It therefore provides a suitable solution for professionals seeking a reliable self-contained breathing apparatus for industrial operations and firefighting activities.
- 3-position rack and pinion system for quick and easy adjustment.
- The GPAL-QS has a sturdy and simple quick-release buckle with a locking mechanism and strap length adjustment.
- The Spiroguide option integrates motion alarm calculation, residual range, heat alarm and data logging.
- Depending on the nature of use and the extreme nature of the interventions without changing the maneuverability of the system, the GPAL-QS plate can be fitted with accessories such as rear plate protection, flexible protection, and handles.
Informations produit
Informations complémentaires
- Weight: 8 to 15.5kg (depending on cylinder type)
- Type of cylinders: 6L to 9L cylinders
- Possibility of installing a twin-cylinder pack (2x6L to 2×7.2L)
Performance
- Autonomy from 20 to 60min (depending on the type of cylinder and the wearer’s consumption)
- Operating temperatures: -30°C to +60°C
Accessoires